What To Do If My Freezer Isn’t Freezing?
If your freezer won’t freeze, a very common cause is a dirty condenser coil. Over time, dust and dirt can build up on the condenser coils, blocking proper airflow and reducing the cooling capacity of the refrigerator. If the freezer evaporator coils are dirty, they won’t work properly. Condenser coils can get dirty or dirty, so airflow can slow down, causing ice to build up on the evaporator coil or inside the refrigerator or freezer.
If the evaporator coils are frozen, the required air will not be able to pass through them, which can cause the freezer to freeze incorrectly. As if too many items in the freezer are blocking ventilation, if there is too much frost or ice in the freezer, the evaporator fans and coils will not work properly. Ice buildup on the freezer walls can hinder the operation of the coils and vents.
For example, if the door does not close properly, moist air can enter the freezer, causing the batteries to freeze. If the freezer is full or the vents are clogged with food, it may block the air circulation and reduce the cooling efficiency of the freezer. Clogged vents can also cause moisture or frost to build up in the freezer.
If one of the fans fails or the compressor is turned off, the refrigerator will cool little or no cooling at all. When the fan is not working properly, the freezer may look fine, but the refrigerator will be hot.
When the freezer fan is running, it means that the defrost timer and the cooling control of the freezer are set to COOL. Most of the time, when the freezer fan is running, the compressor fan should also be running.
If you can hear the compressor motor running and the freezer is still not cooling, the problem may be with the evaporator or condenser coils. If you find that the temperature in your Samsung freezer continues to rise, the compressor and condenser batteries may be the problem. Over time, dirt and dust can build up on the condenser coils, causing them to overheat and making it difficult to maintain the optimum temperature in the freezer.
Its condenser coil cools the refrigerant and continuously removes heat from the freezer until the appropriate temperature is reached inside the freezer. These coils are located inside the freezer and are responsible for lowering the air temperature inside the freezer.
You need to remove the back panel inside the freezer so you can check the coils. Once the coils have thawed, you can reconnect your freezer and start using your freezer as usual.
If you find that your coil is covered with ice due to the freezer door being open, you will need to close the freezer and wait for the coil to defrost. If so, empty the freezer and refrigerator, unplug it, and let the coil thaw for a day or two. To temporarily run the refrigerator, remove the back panel of the refrigerator and remove any frost buildup (preferably fill the evaporator coil with hot water).
To make sure the evaporator fan is not broken and the motor is running, remove the food from the freezer and remove the panel around the fan. To test the evaporator fan motor, the freezer service technician will open the door of the unit and turn the door switch. If the fan motor stops working, the freezer will not be able to maintain cooling and will start freezing.
The evaporator fan motor forces air onto the evaporator coils and circulates in the freezer, if it is not running, the freezer will not cool down. A small fan and motor are mounted next to the evaporator, helping to direct air through the coils and circulate through the refrigerator and freezer. The job of the evaporator fans is to draw cold air from another set of coils to circulate it throughout the unit, first through the freezer and then through the refrigerator (or fresh food compartment).
The refrigerant passes through another set of coils and turns into a gas, making them cold. If the coils are dirty, it will affect the freezer’s ability to keep cool.
During normal operation, the fan draws in moist “warm” air from the back of the freezer and then blows it through the cooling element where it is directed along the front of the freezer. Typically, most refrigerators use a fan to move the cold air in the freezer to the evaporator so that the air is forced into the refrigerator area to keep it cool.
The thermostat maintains the desired temperature of the chest freezer by regulating the power supply to the compressor. When your LG freezer thermostat is working properly, it will inform the freezer control board when to start or stop the refrigeration process. The purpose of the temperature control thermostat is to monitor the temperature in the freezer and then tell the control board what voltage to apply to the evaporator fan motor and compressor so that the freezer can freeze.
Another reason why the freezer works but does not freeze is a faulty evaporator fan. Even a small crack in the door seal can cause the freezer to struggle to maintain a low and stable temperature. Even the freezer and refrigerator door may not seal properly, requiring several different steps to repair.
For freezer repairs in Oklahoma City contact Appliance Repair OKC Services by calling them at 405-378-4566 or you can visit our website at https://www.okcappliance.com or also our Google business page at https://cutt.ly/YEnc8qk. Call today!
The post What To Do If My Freezer Isn’t Freezing? appeared first on Appliance Repair OKC Services | Best Appliance, Washing Machine Repair Company in Oklahoma.